A roof fall occurred in the 4 right crosscut into the #5 entry. The fall was approximately 8' high x 25' long x 18' wide. The fall did not affect workers, ventilation nor equipment. As a continuation the fall also fell into the #5 heading on 4-22-10 appx. 8' high x 18' wide x 10' in length. The area has been cleaned up and resupported.