The roof fall was discovered in the A Mains Section, #9 block, #4 Intersection. The fall was 3100' outby the section tail. The area was bolted with 8' Super Twist bolts and 12' post-tension cable bolts. No one was injured as a result of this fall. No ventilation or equipment was affected.