An unintentional roof fall occurred on the 5A belt line at station 15+40 entry #4. The fall did not affect ventilation, passage of men or cause personal injury. The fall did fall on the belt line and will be cleaned up and arched with steel arches. The fall measured 20' x 20' x 7' thick. The area was devaloped in June of 2006. It was supported with 6' fully grouted roof bolts.