← MSHA accidents

HOISTING

220101370001 · 05/13/2010 · Drummond Company Inc

Details

Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Drummond Company Inc
Operator
Drummond Company Inc
Mine
0102901

Narrative

At approximately 1:35pm the elevator stopped approximately 30 feet from the top landing with two employees on the elevator. The elevator was examined and the cause was found to be the top landing enter lock door switch. The switch was replaced and the elevator was put back in service at approximately 2:07pm.

Source

Authoritative
MSHA Open Government Data
Machine