# FALL OF ROOF OR BACK
> MSHA accident `220101370018` · 05/11/2010 · Alex Energy Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Massey Energy Company
- **Operator:** Alex Energy Inc
- **Mine:** [4608787](https://api.ai-analytics.org/mine/4608787)
## Narrative

An unintentional roof fall occurred on 5/11/10. The fall occurred on #3 belt mains, #5 entry, Bk #10, spad #1277. No injuries occurred from the fall (length 30'-60', width 10', Thickness 6' plus - above anchorage) (support 6' 3/4"" Torque tension, 10' cable volts, and cribs).

---