A roof fall appx. 30'x19'x6'8"" was found on 5-19-2010 in the #6 entry at spad # 810 appx. 2600' from the active face. The roof in this area is mixed and is supported by fully grouted resin bolts and 8"" cable bolts. The fall did not affect ventilation nor was any equipment or miners affected by the fall.