A roof fall occured on the 8 south belt at spad # 43453 between x-cut # 22 & 23. This area was mined around 9/25/2007. The fall was 40 foot long, 19 foot wide and 7 foot high. The are was bolted with 6 foot tention bolts. The fall will be cleaned up and re-bolted.