# HOISTING
> MSHA accident `220101820007` · 06/25/2010 · Morton Salt Div/Morton International Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** K+S Aktiengesellschaft
- **Operator:** Morton Salt Div/Morton International Inc
- **Mine:** [3301993](https://api.ai-analytics.org/mine/3301993)
## Narrative

The South hoist drum brake spring was broken; management chose to make a repair. This was near end 3rd shift; allowed crews to exit during shift change. Repair completed; test done; 1st shift into mine at 7:40. North skip is for emergency evac; South skip had no effect; mine had 2 escapeways.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*