A fall of roof was discovered in the 1st Northwest Mains in the #2 Entry, extending from x-cut 141 to x-cut 142. The fall was approx 150ft long x 19ft wide x 6 1/2ft high. This fall was previously reported on e-document 1066177. Per a discussion with D10 Roof Control Specialist it was determined that (2) separate roof falls could not be recorded on the same 7000-1