# FALL OF ROOF OR BACK
> MSHA accident `220102010003` · 07/08/2010 · GCC Energy LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** GCC SAB de CV
- **Operator:** GCC Energy LLC
- **Mine:** [0504864](https://api.ai-analytics.org/mine/0504864)
## Narrative

Roof fall area was between XC 20 and XC 21 #7 entry of the West Submains. The fall was approximately 35' inby XC 20 and is 25' in length and about 35' outby XC 21. The fall averaged 7' in height and 16' in width. The fall area was originally supported with 6' fully-grouted resin bolts, and was fully meshed.

---