The mine encountered an unintentional roof fall on the Main South, Entry #4 (belt), between XC#62 and #63. The fall measured 40'L X 20'W X avg. 5' thick. The area was developed in April of 2000 and supported with 4' fully grouted bolts. Supplemental support consisted of 6' fully grouted bolts. The fall will be cleaned as per approved site specific plan.