An unplanned roof fall occurred in the #3 entry 40 feet outby spad #113 on the #5 beltline. There were no injuries or equipment involved. Fall area will be rehabilitated. Area was in with 4' resin bolts. 6 cribs had already been installed prior to fall. Ventilation and passage were not affected. State and Federal agencies were notified immediately.