An unintentional roof fall occurred due to the strata broke at and above the anchor point. A smooth slip ran through the entry. The fall occurred in a neutral entry off Unit 2 travelway @ entry 3-4 @ 2+25 east. The fall was approximately 25 ft. long, 18 ft. wide and 1-6 ft. high. Found by mine examiner.