# FALL OF ROOF OR BACK
> MSHA accident `220102290009` · 08/10/2010 · American Energy Corporation
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Robert E  Murray
- **Operator:** American Energy Corporation
- **Mine:** [3301070](https://api.ai-analytics.org/mine/3301070)
## Narrative

Roof fall No. 2 entry to xcut No. 3 was discovered. Fall was approx. 30 feet long by 18 feet wide by 9 feet high. Area was bolted with Install III bolts with resin assisted, with bacon straps and wire mesh screen. Fall was caused by deterioration due to weathering.

---