The mine encountered a roof fall on the Main South Travelway, entry #3, XC #22. The fall measured 5' thick X 21' wide X 27' long. The area was initially bolted with 4' fully grouted bolts. The fall affected the haulage of supplies from the South portal. The fall area will be resupported for travel.