← MSHA accidents

FALL OF ROOF OR BACK

220102420054 · 08/13/2010 · American Energy Corporation

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Robert E Murray
Operator
American Energy Corporation
Mine
3301070

Narrative

We had a roof fall in the South Main #6 entry outby xcut #79 in entry. Fall was 12 feet long, 14 feet wide and 9 feet in height. Roof fall was bolted with Install III with resin assisted, with bacon straps and wire mesh screen on roof fall. This fell above roof bolt anchorage. Fall was caused by deterioration due to weathering.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown