# HOISTING
> MSHA accident `220102670030` · 09/18/2010 · Barrick Turquoise Ridge, Inc.
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Barrick Gold Corp
- **Operator:** Barrick Turquoise Ridge, Inc.
- **Mine:** [2602286](https://api.ai-analytics.org/mine/2602286)
## Narrative

The # 1 secondary hoist electrical feeder cable was found to have a defective splice. This splice was what caused the breakers to trip 09/18/10 at 9:00 pm. #1 secondary hoist was down during repairs of the feeder cable and installation of new pole line fuses.

---