# FALL OF ROOF OR BACK
> MSHA accident `220103080028` · 11/02/2010 · KenAmerican Resources Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Robert E  Murray
- **Operator:** KenAmerican Resources Inc
- **Mine:** [1517741](https://api.ai-analytics.org/mine/1517741)
## Narrative

A roof fall occurred in the 2nd Southwest Mains, crosscut #34 in the intersection of #7 entry. The fall measured approximately 19' x 19' x 10'. The area was supported with 6' tension rebar roof bolts and 8' double lock mega bolts. An undetected slip with the presence of water was determined to be the cause of the fall.

---