# FALL OF ROOF OR BACK
> MSHA accident `220103270046` · 11/17/2010 · Consol of Kentucky Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** CONSOL Energy Inc
- **Operator:** Consol of Kentucky Inc
- **Mine:** [4609307](https://api.ai-analytics.org/mine/4609307)
## Narrative

An unintentional roof fall was discovered in the #2 entry (return) at #36 break spad #676 adjacent to the 1A belt. Size of fall was estimated to be 30'L. x 19'W. x 4-5'H. Fall area had been supported with 4' fully grouted resin bolts. No injuries, no equipment caught. Ventilation was not interrupted. Fall will not be cleaned up.

---