# IGNITION OR EXPLOSION OF GAS OR DUST
> MSHA accident `220103360012` · 11/30/2010 · Jim Walter Resources Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** IGNITION OR EXPLOSION OF GAS OR DUST
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Walter Energy Incorporated
- **Operator:** Jim Walter Resources Inc
- **Mine:** [0101401](https://api.ai-analytics.org/mine/0101401)
## Narrative

IGNITION: The Longwall Shearer was cutting bottom with the Headgate drum when an ignition occurred. It occurred at approximately No. 115 Shield on the H/G Drum. The fire was around the drum and the flame was put out with the drum sprays. No other fire extinguishers or water was used. The fire lasted only a few seconds and went out on it's own.

---