An unintentional roof fall had occurred in an intersection and extended into the crosscut at crosscut 3 in entry 3 on the main east. The fall was approximately 20' x 30' x 12' high. The roof was bolted with 5' point anchor bolts, truss bolted and had 10' point anchor bolts in a star pattern of the intersection.