A roof fall was discovered on this date. The fall is between the #22 & #23 crosscuts in the #4 entry on 2-East Return. The fall measured 70' in length, 20' in width and was 5' in thickness. No persons or equipment was affected. The area was originally supported with 5' HY-Tech bolts. Thea area was dangered off.