Roof fall discovered in return 3900' from working section measuring 80'-150' long, 160' wide, and unknown thickness. Fall was located between #7 and #8 entry, the area was developed 1/20/09 with 4' glue bolts as primary support. Fall was immediately reported and investigated by MSHA.