Roof fall was discovered in return 3200' from working face and measured 50' long, 18.5' wide, 12'thick. Fall was located in Southwest return panel and was developed in 2009, 4' glue bolts were the primary support. Ventilation and passage of men not affected. Fall area will be barricaded and dangered off.