# FALL OF ROOF OR BACK
> MSHA accident `220110420032` · 02/06/2011 · Consol of Kentucky Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** CONSOL Energy Inc
- **Operator:** Consol of Kentucky Inc
- **Mine:** [4605978](https://api.ai-analytics.org/mine/4605978)
## Narrative

An unintentional roof occurred at break 104 in the #4 entry (belt). Size of fall was estimated to be 12'L x 7'W x 3'-31/2'Thick. No injuries, ventilation was not interrupted, belt line was caught. Fall will be cleaned up. The roof had been supported with 6' fully grouted resin bolts

---