A Continuation of a roof fall that was reported on 7/16/2010 was found during a weekly examination. The fall was found in our M4 Mains, X-Cut 72, #3 entry and was the intersection only. It measured 20' X 20' X 15' high. The continuation did not affect passage of miners, affect ventilation, or cause injury to miners.