A roof fall was found in the #4 track entry, between break 17 & 18 the size of the fall was approx. 18' x 22' x 6'. The primary escapeway has been re-routed to #3 belt entry, the effected area will be cleaned and bolted with 10' & 12' rope bolts and 4' glue bolts.