An unintentional roof fall occurred on the #3 Southwest Panel at #1 break in the #1 entry approximately 20 ft outby spad #1129. The fall measured approximately 80 ft x 20 ft x 7 ft high. Area was timbered and dangered off. This fall was discovered during a weekly air way examination.