# MACHINERY
> MSHA accident `220110760035` · 03/11/2011 · Covia Solutions Inc.
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** MACHINERY
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** S C R-Sibelco Nv
- **Operator:** Covia Solutions Inc.
- **Mine:** [0300313](https://api.ai-analytics.org/mine/0300313)
## Narrative

Operator was attempting to lift a preexisting tank, prior to the lift operator had miscalculated the load. The front stabilizer was not deployed and the lift was attempted from the side. The rigging attached to the tank was wrong. When the lift was made the tank twisted and the crane tipped over.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*