# FALL OF ROOF OR BACK
> MSHA accident `220110800001` · 03/18/2011 · ICG Hazard, LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** International Coal Group Inc (ICG)
- **Operator:** ICG Hazard, LLC
- **Mine:** [1518991](https://api.ai-analytics.org/mine/1518991)
## Narrative

A non-injury un-intentional roof fall occurred (outby) on 1 North Main (return) in #2 entry between cross-cut 16 and 17. The dimensions are approximately 40 feet long, 20 feet wide and 6 feet thick. Rod material is laminated shale. The area was initially supported with 60 inch fully grouted resin rods.

---