An unplanned roof fall has occurred in the #3 entry between crosscuts 16 and 17. (#5 belt). Fall was approx 10'thick x 15' wide x 55' long. Fell inby dumping point resulting in K-order and change of RCP. No injuries involoved and the fall did not affect ventilation or travel ways.