# FALL OF ROOF OR BACK
> MSHA accident `220111540022` · 05/26/2011 · Performance Coal Company
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Massey Energy Company
- **Operator:** Performance Coal Company
- **Mine:** [4608436](https://api.ai-analytics.org/mine/4608436)
## Narrative

While mine fireboss examiner was traveling the weekly intake travel way with MSHA inspector a roof fall was discovered in #1 enty at 66 break. Fall measured approx. 4' high, 20' wide and 35' long. Area is under 103 K order and was dangered off. Ventilation and travel is not impeded.

---