An unplanned roof fall occurred on 1 North belt 22 x-cuts from the tailpieces. This area was mined around Feb 1980. The fall was about 5 foot high, 40 foot long, and 19 to 20 foot wide. The area was bolted with 8 foot point anchor. The fall was cleaned up and rebolted and it was cleaned up by the clean up plan.