There was an unintentional fall of roof in the #8 crosscut, off #3 entry at the Clark No.1 mine. Debris from the fall knocked 2-3 blocks out of the return side stopping, this however did not interrupt section ventilation as we had two additional return airways. The area was cribbed off to prevent further roof issues.