A roof fall was found at 11:10p.m. on 7/26/11 at c.c. 118 entry 5 in 6R unit. Area had been mined in 3/10 and top was supported with 8' full resin bolts, 4 cable bolts had also been installed in addition to pattern pins. Clay slip present had weakened roof. No injury or property damage resulted. Access to area has been cribbed off. There are no plans to clean up this fall.