# FALL OF ROOF OR BACK
> MSHA accident `220112150043` · 07/28/2011 · Midland Trail Energy LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Patriot Coal Corporation
- **Operator:** Midland Trail Energy LLC
- **Mine:** [4609297](https://api.ai-analytics.org/mine/4609297)
## Narrative

An unintentional roof fall occurred above anchorage in the #7 entry between #8-#9 cross cuts on Left Mains #3 belt.  The fall measured approximately 7' high by 90' long and 20' wide.  No injuries occurred and ventilation nor travel were blocked by this fall.

---