On 8/4/11, a roof fall found by mine examiner during weekly exams. Fall was inby spad #7932 off 6 east mains. The fall was in an intersection. Fall was approx 24'w by 40'l by 10'h. Fall was in a intake split of air. Fall does not impede ventilation. No injuries no equipment was involved. Area was timbered and cribbed off. This fall will no be cleaned up