An unintentional roof fall occurred on the mmu 015-0 working section entry #5, 3rd left panel off 8th west submain. The fall measured 25'x18'x6.5'and will be cleaned up. It did not affect ventilation, passage of men, or cause personal injury. The area had been roof bolted with 6 foot fully grouted roof bolts.