# IGNITION OR EXPLOSION OF GAS OR DUST
> MSHA accident `220112310043` · 08/12/2011 · Cumberland Coal Resources LP
## Details
- **Degree of injury:** DAYS AWAY FROM WORK ONLY
- **Classification:** IGNITION OR EXPLOSION OF GAS OR DUST
- **Accident type:** Contact with hot objects or substances
- **Occupation:** Electrician, Lineman
- **Activity:** Machine maintenance
- **Injury source:** FLAME,FIRE,SMOKE,NEC
- **Nature of injury:** BURN OR SCALD (HEAT)
- **Body part:** MULTIPLE PARTS (MORE THAN ONE MAJOR)
- **Days lost:** 219
- **Mine experience:** 33.92 years
## Operator
- **Controller:** Alpha Natural Resources, Inc.
- **Operator:** Cumberland Coal Resources LP
- **Mine:** [3605018](https://api.ai-analytics.org/mine/3605018)
## Narrative

A contractor was making modifications to the exhaust ventilation pipe on the 59-3 GOB ventilation borehole with the 9 stage methane exhauster pump operating. The modifications caused methane to be passed over a hot surface causing methane to ignite which resulted in burns to an employee servicing the methane exhauster.

---