# ELECTRICAL
> MSHA accident `220112340054` · 08/17/2011 · S & G Excavating, Inc.
## Details
- **Degree of injury:** DAYS AWAY FROM WORK ONLY
- **Classification:** ELECTRICAL
- **Accident type:** Flash burns (electric)
- **Occupation:** Bulldozer operator, Universal operator, Heavy equipment operator, Operating engineer
- **Activity:** Electrical maintenance
- **Injury source:** ELECTRICAL APPARATUS,NEC
- **Nature of injury:** ELECT.ARC BURN-NOT CONTAC
- **Body part:** MULTIPLE PARTS (MORE THAN ONE MAJOR)
- **Days lost:** 1
- **Mine experience:** 17 years
## Operator
- **Controller:** Kenneth E  Steiner Jr
- **Operator:** S & G Excavating, Inc.
- **Mine:** [1202196](https://api.ai-analytics.org/mine/1202196)
## Narrative

Employee was replacing a fuse in the jaw disconnect box. After throwing the knife in the box, the employee used a fuse puller to remove the bad fuse. When replacing the fuse, the employee got the fuse holder into live electricity and got flashed.

---