A fall occurred in the #9 crosscut, along #1 belt line. The roof fell above the anchor of the 4ft.resin bolts and comprised 5ft of gray, slickensided shale. It measured 40ft x 25ft and it crushed 4 sections of conveyor structure. The area was posted and cribbed, and intersections from #6 to #9 break were bolted with 10ft cable bolts.