A roof fall measuring 22' wide, 18' high, 8' thick fell in the belt entry 1000' outby the working section and outby spad 67301. The area was developed 06/12/11 with 6' torque tension bolts as the primary support. The fall occurred due to laminated rock and coal above the 6' primary supports. No injuries resulted from the fall, belt haulage was affected.