# FALL OF ROOF OR BACK
> MSHA accident `220112430020` · 08/26/2011 · Long Branch Energy
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Long Branch Energy Corporation
- **Operator:** Long Branch Energy
- **Mine:** [4604955](https://api.ai-analytics.org/mine/4604955)
## Narrative

A roof fall occurred 50 feet inby spad no. 11201 in the #5 entry in a four way intersection.  The roof fall measured 40' x 20' x 10' to 12' in thickness.  The area was roof bolted with 3/4"" dia. by 72"" long tension rebar roof bolts and a few 10' to 12' long cable roof bolts.  No injuries occurred.

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*