An unplanned roof fall occurred at crosscut #28 of the 1st Southwest Mains, between entry #4 and entry #5. The primary Roof Support was 6' Tension re-bar bolts, and 9' supplemental support in the intersections. The roof fall occurred 9,951' from the #1 working section. The fall was timbered out with cribs built in intersections connected to area.