A roof fall was discovered in the No 1 return entry of the #2-northwest mains, between break 63 and break 65, just inby survey station #7905. The roof fall was approximately 30'long, by 15' wide and ranged in thickness from 4 1/2' to 5 1/2'. No injuries resulted from the roof fall, and no ventilation effects were detected.