# FALL OF ROOF OR BACK
> MSHA accident `220112900037` · 01/14/2011 · ICG Hazard, LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** International Coal Group Inc (ICG)
- **Operator:** ICG Hazard, LLC
- **Mine:** [1518991](https://api.ai-analytics.org/mine/1518991)
## Narrative

A non-injury unintentional roof fall occurred at the mentioned mine approximately 1000 feet outby the  002 active section. The fall occurred in a neutral entry (#4) in an old roadway intersection on #5 Main. The fall was app. 7 to 8 feet thick, 26 feet wide and 25 feet long. Laminated shale gave way which was supported with 60 inch fully grouted rods.

---