← MSHA accidents

FALL OF ROOF OR BACK

220112940022 · 10/20/2011 · ICG Hazard, LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Arch Resources Inc
Operator
ICG Hazard, LLC
Mine
1518991

Narrative

A non-injury unintentional roof fall occurred on 2 North intake for MMU 002-0 section. The fall was in #8 entry at cross-cut 48 on 2 North Mains in an intersection. The fall was approximately 10 feet thick, 70 feet wide and 20 feet long. This area was initially supported with 60"" fully grouted rods.