# FALL OF ROOF OR BACK
> MSHA accident `220113200002` · 11/06/2011 · Big Ridge Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Peabody Energy Corporation
- **Operator:** Big Ridge Inc
- **Mine:** [1103054](https://api.ai-analytics.org/mine/1103054)
## Narrative

An unplanned roof fall was discovered by MSHA on 11/6/2011 during evaluation of a near by fall.  The fall measured 19'x 40'x 6-8' high.  The fall was in the 1st West Submain off of the 1st North Submain in Entry #6 @ station #29+95. The fall did not affect ventilation, passage of men or cause personal injury.

---