← MSHA accidents

ELECTRICAL

220113360005 · 11/23/2011 · Sidney Coal Company, LLC

Details

Degree of injury
NO DYS AWY FRM WRK,NO RSTR ACT
Classification
ELECTRICAL
Accident type
Contact with electrical current
Occupation
Roof bolter, Rock bolter, Pinner, Mobile roof support operator (MRS)
Activity
Move power cable
Injury source
CONDCTR,ELCT,CBL,TROL POL
Nature of injury
ELECT SHOCK,ELECTROCUTION
Body part
BODY SYSTEMS
Days lost
0
Mine experience
1 years

Operator

Controller (parent)
Alpha Natural Resources, Inc.
Operator
Sidney Coal Company, LLC
Mine
1519097

Narrative

Employee was hanging the cable to the roof bolter, in #3 entry, when he received an electrical shock. He stated that he felt an electrical shock while hanging the cable and next thing he remembered was lying on the ground. He returned to work his next scheduled shift.