# HOISTING
> MSHA accident `220113360007` · 11/25/2011 · Drummond Company Inc
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** 0
- **Mine experience:** — years
## Operator
- **Controller:** Drummond Company Inc
- **Operator:** Drummond Company Inc
- **Mine:** [0102901](https://api.ai-analytics.org/mine/0102901)
## Narrative

While testing the escape hoist at crosscut 66 the hoist would go to the bottom landing but when trying to bring hoist back to the top landing the control fuses would blow. After investigating the problem it was found that the mini processor was bad.

---